↗ ArrowHeadGREEN SHOE GARAGE · QUALITY RECORD

FICTIONAL DEMONSTRATION · ISSUED RECORD

Unit acceptance report

SC-0102

SC-100 · Batch LOT-07 · Fictional · Lost Ridge Instruments

RELEASED · Rail result meets released limits.

ConfigurationRecorded identity
HardwareA
Firmware1.0
SHA-256ff615fdee337220d2981583ce51a472e822035eb742822bbf395467da81f4df7
Approvaldemo-bb3555b61f · quality reviewer · 2026-11-02T21:21:30.983858+00:00
Evidence scopeRuns and attached evidence referenced below. Internal notes excluded.

Acceptance evidence

PT-17 · rev 3 · PASS

completed · 2026-11-02T21:21:30.982523+00:00 · demo-bb3555b61f · manual/82d0b6a35d194f16b8a7d55275f1d2bd

Configuration A / 1.0 · operator asserted

StepRaw resultApproved limitsInstrumentStep verdict
Measure the 5 V rail5.01 V[4.90, 5.10] VSIM-DMM-04pass
Run c6b2d2d0cf6349a7bd3df2bd30a42213 · SHA-256 fc67901b13865fc0255f89724502f5e9d08e5e942e91170e57684cc5801a6082

Referenced files

No files referenced by these runs.